| Property | Result | ASTM Test Method | 
| Wind-driven Rain Resistance | No moisture penetration after 24 hours | Federal Spec. TT-C-555-B | 
| Chemical Resistance | 24 hour exposure to 10 chemicals. Little to no effect. | ASTM-D-1308 | 
| Cold Checking | 10 cold check cycles. No cracking or other deleterious effects. | ASTM-D-1211 | 
| Cold/Hot Cycling | 10 cold/hot check cycles. No cracking or other deleterious effects. (+82 deg. C and -40 deg. C) | US TESTING LAB procedure | 
| Abrasion Resistance | Withstood 450 liters of falling sand abrasion. No wear through. | ASTM-D-968 | 
| Adhesion | Tape cross-hatch method. 100% of coating remained in place. | ASTM-D-3359 | 
| Fire Resistance | Coating did not support combustion. Passed spread of flame Class A. | ASTM-E-108-90-UL/790 | 
| Impact Resistance | Withstood 160 inch pounds. | ASTM-D-2794 | 
| Ponding | After two weeks no water had penetrated the coating systems. | US TESTING LAB procedure | 
| Moisture Vapor Permeability | Average moisture vapor transmission .08 without cracking. | ASTM-D-1653 | 
| Fungal Resistance | Coatings are resistant to fungal contamination. Rating of 10 on a scale of 0 to 10 (resistant). | ASTM-D-3273-73T | 
| Flexibility | Passed the Conical Mandrel test. | ASTM-D-522 | 
| Tensile Strength after weathering | 75% retention of 50 hr. value for each temperature. | ASTM-D-2370 | 
| Accelerated Weathering (2000 hours) | No deleterious effects. | G-26 | 
| Salt Spray (200 hr.) | No deleterious effect. | ASTM-D-1654 | 
| Fire Resistance | Class A, B or C | E-108/UL-790 | 
| Water Vapor Transmission | 20 (inverted cup) | E-96 | 
| Fungicide | 28 days scale 0 (No growth support) | D-3273/3274 G-21 | 
| Algicide | 14 days scale 0 (No growth support) | G-29 | 
| Thermal Physical Properties | (0.90) emissivity and (0.85) reflectivity | C 1371 C1549 | 
| Property | Result | Requirement | ASTM Test Method | 
| Liquid Requirements (Table 1) | |||
| Brookfield Viscosity @ 73.4 F , cps | 15.600 | 12.000 - 85.000  | D 2196 | 
| Viscosity @ 73.4°F , KU | 127 | 85 - 141 | D 562 | 
| Volume Solids, % | 65 | >50 | D 2697 | 
| Weight Solids, % | 69 | >60 | D 1644 | 
| Film Properties (Table 2)  | |||
| Initial Tensile Strength @ 73°F , psi | 288 | 200 minimum | D 2370 | 
| Initial Elongation @ 73°F, % | 284 | 100 minimum  | D 2370 | 
| Permeance (20 mil dry film, 73.4°F/50% RH, inverted), perms | 9.8 | 50 maximum | D 1653 | 
| Water Swelling, Mass % | 13.4 | 20 maximum | D 471 | 
| Wet Adhesion to galvanized metal using ICC Primer B16, pli | 6.5 | 20 minimum | C 794 / D 903 | 
| Wet Adhesion to M HC Concrete Substrate, pli | 5.1 | 2.0 minimum | C 794 / D 903 | 
| Tear Resistance (Die C), lbf/in | 97.0 | >60 | D 624 | 
| Fungi Resistance, rating | 0 | 0 maximum | G 21 | 
| Film Properties after 1000 Hrs Accelerated Weathering | D 4798 | ||
| Elongation @ 73°F, % | 228 | 100 minimum | D 2370 | 
| Low Temperature Flex, 1/2" mandrel, -15°F | Pass | Pass | D 522 | 
| Appearance after 1000 hrs accelerated weathering | Pass | No Cracking or Checking | D 4798 | 
| Initial Radiative Properties of #2000 Finish Surface | |||
| Solar Reflectance | .87 | CRRC .70 | C 1549 | 
| Thermal Emittance | .91 | CRRC .71 | C 1371 | 
Note: Wet adhesion testing was completed using Insulating Coatings Primer B 16 applied to the galvanized metal, allowed to dry, and then the ASTEC #2000 Finish coat applied to the primed galvanized metal. This is the only test that included the use of a primer with the (ASTEC Re-Ply #2000 Finish) coating.
- Tested by PRI Asphalt Technologies, Inc.